Review




Structured Review

Synthes Ltd tomofix plate
Tomofix Plate, supplied by Synthes Ltd, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tomofix/plate+tomofix/pmc12497537-62-2-4
Average 86 stars, based on 1 article reviews
tomofix plate - by Bioz Stars, 2026-10
86/100 stars

Images

Related Articles

Preserving:

Article Title: Is a Complete Anatomical Fit of the Tomofix Plate Biomechanically Favorable? A Parametric Study Using the Finite Element Method
Article Snippet: In response to the challenging requirements of HTO fixation, a large variety of fixation devices have been designed and used in clinical practice, including TomoFix (Synthes Medical, Oberdorf, Switzerland), Puddu (Arthrex Ltd., Naples, FL, USA), PEEKPower (Arthrex, Munich, Germany), iBalance (Arthrex, Munich, Germany), Activemotion (Newclip Technics, Haute-Goulaine, France), Contour Lock (Arthrex, Munich, Germany), and LCfit (Corentec, Cheonan-si, South Korea).

Article Title: Association of Medial Meniscal Volume With Decreased Joint Space Width After Medial Opening-Wedge High Tibial Osteotomy
Article Snippet: The proximal tibial osteotomy site was opened using a lamina spreader, and fixation was achieved using TomoFix (DePuy Synthes or Synthes).

Article Title: Aspekte der Verwendung von homologem Knochen bei Korrekturosteotomien
Article Snippet: The renaissance of open wedge osteotomy, such as medial opening wedge high tibial osteotomy, is accompanied by a relevant potential for delayed bone healing, non-union and postoperative loss of correction.. The use of bone substitute materials is principally suitable to reduce the complication rate of osteotomy.. The transplantation of autologous bone from the iliac crest remains the gold standard for treating osseous defects.

Article Title: Combined proximal tibial osteotomy for varus osteoarthritis of the knee: Biomechanical tests and finite-element analyses.
Article Snippet: Please cite this article as: W. Ji, C. Luo, S. Zh mechanical tests and fin..., The Knee, https Article history: Received 20 October 2019 Received in revised form 28 November 2019 Accepted 22 January 2020 Available online xxxx Background: A special combined proximal tibial osteotomy (CPTO) was designed to correct varus osteoarthritis of the knee with severe intra-articular pathologies, which could not be fully corrected by opening-wedge high tibial osteotomy (OWHTO).. The biomechanical strength of the CPTO bone–implant construct was evaluated and compared with those of existing osteotomy methods.. Methods: Three variations of osteotomy including OWHTO, tibial condylar valgus osteotomy (TCVO), and CPTO were performed on synthetic bones with locking plate and screws.

Article Title: Clinical outcome and complications after simultaneous bilateral medial opening-wedge high tibial osteotomy.
Article Snippet: Background: The literature provides limited evidence regarding postoperative outcomes and complications following simultaneous bilateral medial opening-wedge high tibial osteotomy (MOWHTO).. This study aimed to investigate the clinical outcomes and complications associated with simultaneous bilateral MOWHTO.. Methods: We retrospectively evaluated 72 knees from 36 patients (mean age, 58.6 ± 8.2 y ears) who underwent simultaneous bilateral MOWHTOs between December 2011 and January 2021.

Article Title: Geometrical Planning of the Medial Opening Wedge High Tibial Osteotomy—An Experimental Approach
Article Snippet: This paper aims to experimentally investigate the behavior of the tibia with an open wedge osteotomy fixed with a locking plate, TomoFix (DE Puy Synthes), taking into account two positions of the mechanical axis of the leg on the width of the tibial plateau, measured from medial to lateral at 50% and 62.5% (Fujisawa point), respectively.

Article Title: Medial Opening-Wedge High Tibial Osteotomy for Medial Compartment Arthrosis/Overload.
Article Snippet: Disclosures: Dr B.R.. Wolf reports the following disclosures: AAOS: Board or committee member; American Orthopedic Society for Sports Medicine: Board or committee member; Arthrex, Inc: Other financial or material support; CONMED Linvatec: Paid consultant; Mid America Orthopedic Association: Board or committee member; Orthopaedic Research and Education Foundation (OREF), United States: Research support; Orthopedic Journal of Sports Medicine: Editorial or governing board; Smith and Nephew: Other financial or material support. a Department of Orthopedics and Rehabilitation, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA 52242, USA; b Department of Orthopedics and Rehabilitation, University of Iowa Hospitals and Clinics, University of Iowa Athletics, 2701 Prairie Meadow Drive, Iowa City, IA 52240, USA * Corresponding author.. E-mail address: molly-day@uiowa.edu

Clinical Proteomics:

Article Title: Is a Complete Anatomical Fit of the Tomofix Plate Biomechanically Favorable? A Parametric Study Using the Finite Element Method
Article Snippet: In response to the challenging requirements of HTO fixation, a large variety of fixation devices have been designed and used in clinical practice, including TomoFix (Synthes Medical, Oberdorf, Switzerland), Puddu (Arthrex Ltd., Naples, FL, USA), PEEKPower (Arthrex, Munich, Germany), iBalance (Arthrex, Munich, Germany), Activemotion (Newclip Technics, Haute-Goulaine, France), Contour Lock (Arthrex, Munich, Germany), and LCfit (Corentec, Cheonan-si, South Korea).

Article Title: Association of Medial Meniscal Volume With Decreased Joint Space Width After Medial Opening-Wedge High Tibial Osteotomy
Article Snippet: The proximal tibial osteotomy site was opened using a lamina spreader, and fixation was achieved using TomoFix (DePuy Synthes or Synthes).

Article Title: Aspekte der Verwendung von homologem Knochen bei Korrekturosteotomien
Article Snippet: The renaissance of open wedge osteotomy, such as medial opening wedge high tibial osteotomy, is accompanied by a relevant potential for delayed bone healing, non-union and postoperative loss of correction.. The use of bone substitute materials is principally suitable to reduce the complication rate of osteotomy.. The transplantation of autologous bone from the iliac crest remains the gold standard for treating osseous defects.

Article Title: Combined proximal tibial osteotomy for varus osteoarthritis of the knee: Biomechanical tests and finite-element analyses.
Article Snippet: Please cite this article as: W. Ji, C. Luo, S. Zh mechanical tests and fin..., The Knee, https Article history: Received 20 October 2019 Received in revised form 28 November 2019 Accepted 22 January 2020 Available online xxxx Background: A special combined proximal tibial osteotomy (CPTO) was designed to correct varus osteoarthritis of the knee with severe intra-articular pathologies, which could not be fully corrected by opening-wedge high tibial osteotomy (OWHTO).. The biomechanical strength of the CPTO bone–implant construct was evaluated and compared with those of existing osteotomy methods.. Methods: Three variations of osteotomy including OWHTO, tibial condylar valgus osteotomy (TCVO), and CPTO were performed on synthetic bones with locking plate and screws.

Article Title: Clinical outcome and complications after simultaneous bilateral medial opening-wedge high tibial osteotomy.
Article Snippet: Background: The literature provides limited evidence regarding postoperative outcomes and complications following simultaneous bilateral medial opening-wedge high tibial osteotomy (MOWHTO).. This study aimed to investigate the clinical outcomes and complications associated with simultaneous bilateral MOWHTO.. Methods: We retrospectively evaluated 72 knees from 36 patients (mean age, 58.6 ± 8.2 y ears) who underwent simultaneous bilateral MOWHTOs between December 2011 and January 2021.

Article Title: Geometrical Planning of the Medial Opening Wedge High Tibial Osteotomy—An Experimental Approach
Article Snippet: This paper aims to experimentally investigate the behavior of the tibia with an open wedge osteotomy fixed with a locking plate, TomoFix (DE Puy Synthes), taking into account two positions of the mechanical axis of the leg on the width of the tibial plateau, measured from medial to lateral at 50% and 62.5% (Fujisawa point), respectively.

Article Title: Medial Opening-Wedge High Tibial Osteotomy for Medial Compartment Arthrosis/Overload.
Article Snippet: Disclosures: Dr B.R.. Wolf reports the following disclosures: AAOS: Board or committee member; American Orthopedic Society for Sports Medicine: Board or committee member; Arthrex, Inc: Other financial or material support; CONMED Linvatec: Paid consultant; Mid America Orthopedic Association: Board or committee member; Orthopaedic Research and Education Foundation (OREF), United States: Research support; Orthopedic Journal of Sports Medicine: Editorial or governing board; Smith and Nephew: Other financial or material support. a Department of Orthopedics and Rehabilitation, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA 52242, USA; b Department of Orthopedics and Rehabilitation, University of Iowa Hospitals and Clinics, University of Iowa Athletics, 2701 Prairie Meadow Drive, Iowa City, IA 52240, USA * Corresponding author.. E-mail address: molly-day@uiowa.edu

Injection:

Article Title: Is a Complete Anatomical Fit of the Tomofix Plate Biomechanically Favorable? A Parametric Study Using the Finite Element Method
Article Snippet: In response to the challenging requirements of HTO fixation, a large variety of fixation devices have been designed and used in clinical practice, including TomoFix (Synthes Medical, Oberdorf, Switzerland), Puddu (Arthrex Ltd., Naples, FL, USA), PEEKPower (Arthrex, Munich, Germany), iBalance (Arthrex, Munich, Germany), Activemotion (Newclip Technics, Haute-Goulaine, France), Contour Lock (Arthrex, Munich, Germany), and LCfit (Corentec, Cheonan-si, South Korea).

Article Title: Association of Medial Meniscal Volume With Decreased Joint Space Width After Medial Opening-Wedge High Tibial Osteotomy
Article Snippet: The proximal tibial osteotomy site was opened using a lamina spreader, and fixation was achieved using TomoFix (DePuy Synthes or Synthes).

Article Title: Aspekte der Verwendung von homologem Knochen bei Korrekturosteotomien
Article Snippet: The renaissance of open wedge osteotomy, such as medial opening wedge high tibial osteotomy, is accompanied by a relevant potential for delayed bone healing, non-union and postoperative loss of correction.. The use of bone substitute materials is principally suitable to reduce the complication rate of osteotomy.. The transplantation of autologous bone from the iliac crest remains the gold standard for treating osseous defects.

Article Title: Combined proximal tibial osteotomy for varus osteoarthritis of the knee: Biomechanical tests and finite-element analyses.
Article Snippet: Please cite this article as: W. Ji, C. Luo, S. Zh mechanical tests and fin..., The Knee, https Article history: Received 20 October 2019 Received in revised form 28 November 2019 Accepted 22 January 2020 Available online xxxx Background: A special combined proximal tibial osteotomy (CPTO) was designed to correct varus osteoarthritis of the knee with severe intra-articular pathologies, which could not be fully corrected by opening-wedge high tibial osteotomy (OWHTO).. The biomechanical strength of the CPTO bone–implant construct was evaluated and compared with those of existing osteotomy methods.. Methods: Three variations of osteotomy including OWHTO, tibial condylar valgus osteotomy (TCVO), and CPTO were performed on synthetic bones with locking plate and screws.

Article Title: Clinical outcome and complications after simultaneous bilateral medial opening-wedge high tibial osteotomy.
Article Snippet: Background: The literature provides limited evidence regarding postoperative outcomes and complications following simultaneous bilateral medial opening-wedge high tibial osteotomy (MOWHTO).. This study aimed to investigate the clinical outcomes and complications associated with simultaneous bilateral MOWHTO.. Methods: We retrospectively evaluated 72 knees from 36 patients (mean age, 58.6 ± 8.2 y ears) who underwent simultaneous bilateral MOWHTOs between December 2011 and January 2021.

Article Title: Geometrical Planning of the Medial Opening Wedge High Tibial Osteotomy—An Experimental Approach
Article Snippet: This paper aims to experimentally investigate the behavior of the tibia with an open wedge osteotomy fixed with a locking plate, TomoFix (DE Puy Synthes), taking into account two positions of the mechanical axis of the leg on the width of the tibial plateau, measured from medial to lateral at 50% and 62.5% (Fujisawa point), respectively.

Article Title: Medial Opening-Wedge High Tibial Osteotomy for Medial Compartment Arthrosis/Overload.
Article Snippet: Disclosures: Dr B.R.. Wolf reports the following disclosures: AAOS: Board or committee member; American Orthopedic Society for Sports Medicine: Board or committee member; Arthrex, Inc: Other financial or material support; CONMED Linvatec: Paid consultant; Mid America Orthopedic Association: Board or committee member; Orthopaedic Research and Education Foundation (OREF), United States: Research support; Orthopedic Journal of Sports Medicine: Editorial or governing board; Smith and Nephew: Other financial or material support. a Department of Orthopedics and Rehabilitation, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA 52242, USA; b Department of Orthopedics and Rehabilitation, University of Iowa Hospitals and Clinics, University of Iowa Athletics, 2701 Prairie Meadow Drive, Iowa City, IA 52240, USA * Corresponding author.. E-mail address: molly-day@uiowa.edu

Functional Assay:

Article Title: Is a Complete Anatomical Fit of the Tomofix Plate Biomechanically Favorable? A Parametric Study Using the Finite Element Method
Article Snippet: In response to the challenging requirements of HTO fixation, a large variety of fixation devices have been designed and used in clinical practice, including TomoFix (Synthes Medical, Oberdorf, Switzerland), Puddu (Arthrex Ltd., Naples, FL, USA), PEEKPower (Arthrex, Munich, Germany), iBalance (Arthrex, Munich, Germany), Activemotion (Newclip Technics, Haute-Goulaine, France), Contour Lock (Arthrex, Munich, Germany), and LCfit (Corentec, Cheonan-si, South Korea).

Article Title: Association of Medial Meniscal Volume With Decreased Joint Space Width After Medial Opening-Wedge High Tibial Osteotomy
Article Snippet: The proximal tibial osteotomy site was opened using a lamina spreader, and fixation was achieved using TomoFix (DePuy Synthes or Synthes).

Article Title: Aspekte der Verwendung von homologem Knochen bei Korrekturosteotomien
Article Snippet: The renaissance of open wedge osteotomy, such as medial opening wedge high tibial osteotomy, is accompanied by a relevant potential for delayed bone healing, non-union and postoperative loss of correction.. The use of bone substitute materials is principally suitable to reduce the complication rate of osteotomy.. The transplantation of autologous bone from the iliac crest remains the gold standard for treating osseous defects.

Article Title: Combined proximal tibial osteotomy for varus osteoarthritis of the knee: Biomechanical tests and finite-element analyses.
Article Snippet: Please cite this article as: W. Ji, C. Luo, S. Zh mechanical tests and fin..., The Knee, https Article history: Received 20 October 2019 Received in revised form 28 November 2019 Accepted 22 January 2020 Available online xxxx Background: A special combined proximal tibial osteotomy (CPTO) was designed to correct varus osteoarthritis of the knee with severe intra-articular pathologies, which could not be fully corrected by opening-wedge high tibial osteotomy (OWHTO).. The biomechanical strength of the CPTO bone–implant construct was evaluated and compared with those of existing osteotomy methods.. Methods: Three variations of osteotomy including OWHTO, tibial condylar valgus osteotomy (TCVO), and CPTO were performed on synthetic bones with locking plate and screws.

Article Title: Clinical outcome and complications after simultaneous bilateral medial opening-wedge high tibial osteotomy.
Article Snippet: Background: The literature provides limited evidence regarding postoperative outcomes and complications following simultaneous bilateral medial opening-wedge high tibial osteotomy (MOWHTO).. This study aimed to investigate the clinical outcomes and complications associated with simultaneous bilateral MOWHTO.. Methods: We retrospectively evaluated 72 knees from 36 patients (mean age, 58.6 ± 8.2 y ears) who underwent simultaneous bilateral MOWHTOs between December 2011 and January 2021.

Article Title: Geometrical Planning of the Medial Opening Wedge High Tibial Osteotomy—An Experimental Approach
Article Snippet: This paper aims to experimentally investigate the behavior of the tibia with an open wedge osteotomy fixed with a locking plate, TomoFix (DE Puy Synthes), taking into account two positions of the mechanical axis of the leg on the width of the tibial plateau, measured from medial to lateral at 50% and 62.5% (Fujisawa point), respectively.

Article Title: Medial Opening-Wedge High Tibial Osteotomy for Medial Compartment Arthrosis/Overload.
Article Snippet: Disclosures: Dr B.R.. Wolf reports the following disclosures: AAOS: Board or committee member; American Orthopedic Society for Sports Medicine: Board or committee member; Arthrex, Inc: Other financial or material support; CONMED Linvatec: Paid consultant; Mid America Orthopedic Association: Board or committee member; Orthopaedic Research and Education Foundation (OREF), United States: Research support; Orthopedic Journal of Sports Medicine: Editorial or governing board; Smith and Nephew: Other financial or material support. a Department of Orthopedics and Rehabilitation, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA 52242, USA; b Department of Orthopedics and Rehabilitation, University of Iowa Hospitals and Clinics, University of Iowa Athletics, 2701 Prairie Meadow Drive, Iowa City, IA 52240, USA * Corresponding author.. E-mail address: molly-day@uiowa.edu

Shear:

Article Title: Is a Complete Anatomical Fit of the Tomofix Plate Biomechanically Favorable? A Parametric Study Using the Finite Element Method
Article Snippet: In response to the challenging requirements of HTO fixation, a large variety of fixation devices have been designed and used in clinical practice, including TomoFix (Synthes Medical, Oberdorf, Switzerland), Puddu (Arthrex Ltd., Naples, FL, USA), PEEKPower (Arthrex, Munich, Germany), iBalance (Arthrex, Munich, Germany), Activemotion (Newclip Technics, Haute-Goulaine, France), Contour Lock (Arthrex, Munich, Germany), and LCfit (Corentec, Cheonan-si, South Korea).

Article Title: Association of Medial Meniscal Volume With Decreased Joint Space Width After Medial Opening-Wedge High Tibial Osteotomy
Article Snippet: The proximal tibial osteotomy site was opened using a lamina spreader, and fixation was achieved using TomoFix (DePuy Synthes or Synthes).

Article Title: Aspekte der Verwendung von homologem Knochen bei Korrekturosteotomien
Article Snippet: The renaissance of open wedge osteotomy, such as medial opening wedge high tibial osteotomy, is accompanied by a relevant potential for delayed bone healing, non-union and postoperative loss of correction.. The use of bone substitute materials is principally suitable to reduce the complication rate of osteotomy.. The transplantation of autologous bone from the iliac crest remains the gold standard for treating osseous defects.

Article Title: Combined proximal tibial osteotomy for varus osteoarthritis of the knee: Biomechanical tests and finite-element analyses.
Article Snippet: Please cite this article as: W. Ji, C. Luo, S. Zh mechanical tests and fin..., The Knee, https Article history: Received 20 October 2019 Received in revised form 28 November 2019 Accepted 22 January 2020 Available online xxxx Background: A special combined proximal tibial osteotomy (CPTO) was designed to correct varus osteoarthritis of the knee with severe intra-articular pathologies, which could not be fully corrected by opening-wedge high tibial osteotomy (OWHTO).. The biomechanical strength of the CPTO bone–implant construct was evaluated and compared with those of existing osteotomy methods.. Methods: Three variations of osteotomy including OWHTO, tibial condylar valgus osteotomy (TCVO), and CPTO were performed on synthetic bones with locking plate and screws.

Article Title: Clinical outcome and complications after simultaneous bilateral medial opening-wedge high tibial osteotomy.
Article Snippet: Background: The literature provides limited evidence regarding postoperative outcomes and complications following simultaneous bilateral medial opening-wedge high tibial osteotomy (MOWHTO).. This study aimed to investigate the clinical outcomes and complications associated with simultaneous bilateral MOWHTO.. Methods: We retrospectively evaluated 72 knees from 36 patients (mean age, 58.6 ± 8.2 y ears) who underwent simultaneous bilateral MOWHTOs between December 2011 and January 2021.

Article Title: Geometrical Planning of the Medial Opening Wedge High Tibial Osteotomy—An Experimental Approach
Article Snippet: This paper aims to experimentally investigate the behavior of the tibia with an open wedge osteotomy fixed with a locking plate, TomoFix (DE Puy Synthes), taking into account two positions of the mechanical axis of the leg on the width of the tibial plateau, measured from medial to lateral at 50% and 62.5% (Fujisawa point), respectively.

Article Title: Medial Opening-Wedge High Tibial Osteotomy for Medial Compartment Arthrosis/Overload.
Article Snippet: Disclosures: Dr B.R.. Wolf reports the following disclosures: AAOS: Board or committee member; American Orthopedic Society for Sports Medicine: Board or committee member; Arthrex, Inc: Other financial or material support; CONMED Linvatec: Paid consultant; Mid America Orthopedic Association: Board or committee member; Orthopaedic Research and Education Foundation (OREF), United States: Research support; Orthopedic Journal of Sports Medicine: Editorial or governing board; Smith and Nephew: Other financial or material support. a Department of Orthopedics and Rehabilitation, University of Iowa Hospitals and Clinics, 200 Hawkins Drive, Iowa City, IA 52242, USA; b Department of Orthopedics and Rehabilitation, University of Iowa Hospitals and Clinics, University of Iowa Athletics, 2701 Prairie Meadow Drive, Iowa City, IA 52240, USA * Corresponding author.. E-mail address: molly-day@uiowa.edu



Similar Products

86
Synthes Ltd tomofix plate
Tomofix Plate, supplied by Synthes Ltd, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tomofix/plate+tomofix/pmc12497537-62-2-4
Average 86 stars, based on 1 article reviews
tomofix plate - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

90
DePuy Synthes locking compression plate fixation system tomofix
Locking Compression Plate Fixation System Tomofix, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tomofix/medial+locking+compression+plate+tomofix/10__1016_slash_j__jcjp__2025__100254-64-51-57
Average 90 stars, based on 1 article reviews
locking compression plate fixation system tomofix - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
DePuy Synthes locking plates tomofix mdf
Locking Plates Tomofix Mdf, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tomofix/tomofix+mdf+plate/pm40420405-70-17-21
Average 90 stars, based on 1 article reviews
locking plates tomofix mdf - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
DePuy Synthes angular stable plate tomofix
Angular Stable Plate Tomofix, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tomofix/angular+stable+plates+tomofix/pmc12086801-93-7-11
Average 90 stars, based on 1 article reviews
angular stable plate tomofix - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Synthes Ltd standard tomofix plate
Standard Tomofix Plate, supplied by Synthes Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tomofix/tomofix+plate/pm40186958-47-55-34
Average 90 stars, based on 1 article reviews
standard tomofix plate - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Arthrex Inc osteotomy plate tomofix
Osteotomy Plate Tomofix, supplied by Arthrex Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tomofix/tomofix+plate/pm40327210-78-5-10
Average 90 stars, based on 1 article reviews
osteotomy plate tomofix - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
DePuy Synthes tomofix system
Tomofix System, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tomofix/tomofix/pm40230218-71-12-14
Average 90 stars, based on 1 article reviews
tomofix system - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
DePuy Synthes locking plate system tomofix
Locking Plate System Tomofix, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/tomofix/locking+plate+tomofix/pm40235425-73-6-10
Average 90 stars, based on 1 article reviews
locking plate system tomofix - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

Image Search Results